- Keep waveguide and coax dry
- Distributes dry low pressure air from one or more sources to one or more transmission lines
- Continuous system monitoring allows leaking lines to be isolated while the rest of the system remains pressurized
- Periodic automated line testing can identify future line leaks for planning maintenance before critical failures
- Highly configurable to meet the needs of wide ranging applications Programmable operating pressure range: 0.10 psig - 7.50 psig (7mbar - 517mbar)
- Programmable pressure relief valve to bleed off excess system pressure common with high solar gains
- Future-proof software based features allow updates and upgrades while in service
- Remote monitoring and control with web interface or SNMP
- Configurable Parallel Pumping operation combines multiple ADH NETCOM dehydrators for increased system capacity
- Configurable Redundant Pumping operation combines multiple ADH
- NETCOM dehydrators for increased system reliability
- Ethernet, RS-422/485, RS-232 and alarm relay outputs for compatibility with nearly any system
- Simple power connections for 100-240 VAC or ±20-75 VDC
Enclosure
Dimensions |
17" × 12" × 5-1/4" (432mm × 305mm × 133mm) |
Weight |
11 lbs (5kg) |
Mounting |
Dual-post rack, flush mounted Single-post rack, center mounted Wall mounted |
Power
Supply voltage |
100-240 VAC, 50/60 Hz | ±20-75 VDC |
Weight |
1.0 Amps at 100 V |
Mounting |
60 W max |
Heat dissipation |
205 BTU/hr max |
Output
Maximum pressure |
7.5 psig (517mbar) |
Pressure relief valve |
8 psig (522mbar) |
Display units |
SI (milibars); English(psig), default |
Ports |
8 x 1/8 NPT(2 input, 5 outlet and pressure relief valve default) 3/8” or ¼” hose barbs(both included) |
Control
Protocols |
HTTP(Web Interfaces), SNMP, UDP, TFTP |
Maximum Pressure |
Configurable Range: 0.20 psig – 7.5 psig(14mbar - 517mbar), Default: 0.50 psig (34.5mbar) |
Minimum Pressure |
Configurable Range: 0.10 psig - 7.4 psig (7mbar - 510mbar), Default: 0.30 psig (21mbar) |
Low pressure alarm level |
User Configurable, Default: 0.15 psig (10mbar |
High pressure alarm level |
User Configurable, Default: 1.5 psig (103.5mbar) |
Alarm relays |
Contact Type - Form C, SPDT, reverse acting Ratings - 0.25 Amps @ 60 V
User Configurable, Defaults - Alarm Relay 1: Summary Alarm, Alarm Relay 2: Low Pressure Alarm, Alarm Relay 3: Over Pressure Alarm User Configurable, Default: 50% User Configurable, Default: Standard/Slave |
Parallel pumping configuration |
User configurable, Default: Off |
Redundant pumping |
User configurable, Default: Off |