Quintech USC-1951 Universal Switch Chassis with Ethernet Interface

Search
Part Number: QT-USC1951 Categories , Brand:

Quintech USC-1951 Universal Switch Chassis with Ethernet Interface

The USC 1951 universal switching system is a single RU, dual bay chassis that accepts up to two modular A/B switch cards in a variety of combinations, providing a highly flexible and reconfigurable switching solution. The universal switch chassis can be used in either a single or dual channel configuration and can be easily upgraded or reconfigured in the field. The USC 1951 system is currently available with five different card options, including A/B switching and RF sensing cards for L-band, broadband and ASI signals. For control purposes, both serial, Ethernet and an optional built-in web interface are available.

Pricing Varies

Configuration flexibility with up to 2 switch cards in a single chassis. Converges RF sensing redundancy, switching, monitoring and/or signal distribution into a 1 RU chassis. Card Frequency Bands: ASI, CATV (47-862 MHz), L-band (950-2150 MHz) or Wideband (DC-2.5 GHz) Card-based design enables the user to easily upgrade or reconfigure in the field with no tools or cables. RS-232 or RS-422 or RS-485 or Ethernet remote control.
Specifications: Universal Switch Chassis Number of Functional Cards/Slots: 1 or 2 Remote Interface: RS-232 or RS-422 or RS-485, and Ethernet Connector: Sub D-9 (female) Two Stage Alarm Signalization: Form “C” Relay Contacts Alarm Connector: Sub D-9 (male) Alarm Contact Load: 60V @ 0.3A B-Alarm: One of the power supplies does not deliver any secondary power A-Alarm: Both power supplies do not deliver any secondary power Summary Alarm: Via remote interface and Form “C” Contact Closure Redundant Power Supplies: 100–260 V~, 50/60 Hz Power Consumption: 40 W Mechanical: 19” W x 1.73” H x 10.24” D Weight: 11.02 lbs. Environmental: 0°-40° C and 95% non-condensing humidity
Available Modules: USC 11-0005 DPST Switch Module A 2x1 switch card operates in the 47-862 MHz frequency range and contains 75Ù BNC connectors.  The output port can be connected to one of two input ports.  A monitoring output port is also provided for measurement purposes. [DC Block] Frequency Range: 47 – 862 MHz Input/Output Connectors: Type “F”, 75 Ù (female) Return Loss (selected path): > 23 dB @ 70 MHz > 18 dB @ 140 MHz > 14 dB @ 700 MHz (typical 16 dB) Return Loss (non-selected path): > 23 dB @ 70 MHz > 18 dB @ 140 MHz > 14 dB @ 700 MHz (typical 16 dB) Insertion Loss: < 2 dB Isolation On/Off: > 80 dB @ 140 MHz, > 55 dB @ 700 MHz Relay Type: Failsafe Max. Input Power: + 30 dBm Switching Cycles: 10E6 Insertion Loss Monitor Output: -20 dB nominal + 3 dB Return Loss Monitor Output: > 18 dB -------------------------------------------------------------------------------- USC 11-0007 & USC 11-0009 SPDT Ultra Broadband Modules An SPDT ultra broadband switch card operates in the DC – 2.5 GHz frequency range and contains Type “F” (USC 11-0007) or BNC (USC 11-0009) connectors. The common port can be switched to one of two input/output ports. Frequency Range: DC – 2.5 GHz Input/Output Connectors: Type “F”, 75 Ù (female), BNC 75 Ù or BNC 50 Ù Return Loss (selected path): > 14 dB (typical 16 dB) Return Loss (non-selected path): > 14 dB (typical 16 dB) Insertion Loss: < 2 dB Isolation On/Off: Latching Relay Type: > 50 dB Switching Cycles: > 10E6 (no DC) > 10E5 (0.25A, 28 VDC) Max. Input Power: + 30 dBm -------------------------------------------------------------------------------- USC 11-0010 L-Band DPST Sensing Switch Module A 2x1 RF sensing switch card operates in the 950-2150 MHz frequency range and contains 75Ù F connectors.  Two input ports can be switched to one output port.  Both input channels are individually monitored for a user-defined RF threshold level.  Alarm capabilities are also provided. [Do Not Apply DC] Frequency Range: 950 – 2150 MHz (L-band) RF Connectors: Type F, 75 Ù (female) Damage Level:           +15 dBm Input Power: < 0 dBm Adjustable Switching Threshold: -50 to -10 dBm Return Loss (Selected Path): > 14 dB (typical 16 dB) Return Loss (Non-selected Path): > 14 dB (typical 16 dB) Insertion Loss: < 2 dB Amplitude Frequency Response: + 0.5 dB Switching Cycles: > 10E6 (no DC) -------------------------------------------------------------------------------- USC 11-0011 DPST Sensing Switch Module A 2x1 RF sensing switch card that operates in the 47 – 862 MHz frequency range and contains 75Ù F connectors.  Two input ports can be switched to one output port.  Both input channels are individually monitored for a user-defined RF threshold.  An external controller can be used to control the switch.  Alarm capabilities are also provided. [Do Not Apply DC] Frequency Range: 47 – 862 MHz RF Connectors: Type F, 75 Ù (female) Damage Level: +10 dBm Input Power: < 0 dBm Adjustable Switching Threshold: -60 to -10 dBm Return Loss (Selected Path): > 14 dB (typical 16 dB) Return Loss (Non-selected Path): > 14 dB (typical 16 dB) Insertion Loss: < 2 dB Amplitude Frequency Response: + 0.5 dB Switching Cycles: > 10E6 (no DC) -------------------------------------------------------------------------------- USC 14-0001 ASI Redundancy Switch Module A redundancy card that combines a 2x1 switch with a 1x3 active distribution amplifier for ASI signals.  One of two inputs feeds the 3 parallel outputs. In the event of power failure, the default signal path is Input A to Output 1 only. [DC Block] Frequency Range: 30 – 540 Mbit RF Connectors: BNC, 75 Ù (female) No. of Input Ports: 2 No. of Output Ports: 3 Input Level: 100 mV – 800 mV Output Level: > 600 mV Isolation On/Off: > 50 mV Switching Cycles: > 10E6 Relay Type: Failsafe Signal:  ASI / 0.8V

Product Categories